AKN- Full vacuum Automatic Chlorinator M 3610 C

Địa chỉ: Số 1, Đường 61, Phường Tân Kiểng, Quận 7, TP.HCM

Hotline: 0902464668

Tiếng Việt Tiếng Anh
AKN- Full vacuum Automatic Chlorinator M 3610 C

AKN- Full vacuum Automatic Chlorinator M 3610 C

  • 0
  • Liên hệ
  • - +
  • 1495

Capacity up to 15 kg/h

  • 4 –20 mA proportional control input
  • Modbus Communication
  • 5-POINT valve calibration
  • Manual or automatic control
  • Led indication of the valve position
  • Vacuum indication
  • Made of quality materials
  • High quality stepper motor
  • V-notch precision rate valve
  • Thông tin sản phẩm
  • Thông số kỹ thuật
  • Tài liệu

General

Automatic chlorinator series M 3610 C is a heavy duty feed unit intended for accurate manual or automatic feed of chlorine gas. The unit is controlled via controller (automatic control) or in case of need it can simply be switched to manual control.

The unit M 3610 C consist of:

  • Motor rate valve series M 3531 C 
  • ERB gas flow meter of corresponding capacity with manual rate valve
  • Vacuum switch (high/low)
  • Vacuum gauge 
  • Wall mounting board with piping 
  • DP regulator

Electromotive rate valve Series M 3531 C is made of compact plastic, resistant to high concentration of chlorine, precision rate valve and quality driving motor. Gas flowmeter is also made of compact plastic and glass, resistant to high concentration of chlorine and precision manual rate valve. All seals are made of materials resistant to aggressive gases (FKM, PTFE, PVDF). Differential pressure regulator is available in case of long vacuum lines or fluctuating vacuum.

General

One must have in mind that M 3610 C is a vacuum device, therefore gases are not pushed, but sucked through. Gas enters in inlet and goes through the gas flow meter. Next, through the needle of rate valve, desired quantity is provided. Then, gas enters the DP REGLATOR, where vacuum fluctuations are reduced. Last element is check valve that disables backflow.

Automatic chlorinator is connected to AQUACON M 5500 C or AQUAProcessor series M 5700 C, which opens or closes the motor valve on chlorinator according to the signal received from water flow meter and/or residual chlorine analyser. In case of controller malfunction, the feed rate can easily be set manually on the motor valve. In case of motor valve failure, manual feed can be adjusted by rate valve on the gas flow meter.

Motor valve can then easily be dismounted from chlorinator. When repaired, it can easily be assembled back and set into operation.

Sản phẩm cùng loại
0
Zalo
Hotline